Autoclave Class Summary

 Autoclave Class Autoclave Class Summary

Class N Autoclaves

The Lowest Class. 

No Vacuum pump so you can only sterilise instruments with a solid (not hollow) structure, and which are unpackaged.

Class S Autoclaves

The Middle Class.

Single stage vacuum pump. suitable for the sterilisation of single-packed, multilayer packed and more massive instruments, which you cannot sterilise in class N autoclaves.

Class B Autoclaves

TheHighest Class. 

Features a fractionated pre-vacuum that completely removes air from the chamber. These are what hospitals, medical centres, and dental clinics usually use for their instruments.

ProMedCo is an enterprising and innovative 100% Australian-owned and operated company.

We help businesses like yours with infection control products, equipment and training.

ProMedCo wants to bring a new level of service and innovation to the industry and encourage our team to think differently, share great ideas and create effective outcomes for our clients.

Since its inception, ProMedCo has grown into the well-known brand it is today supplying healthcare professionals across Australia with quality products at great prices.

Understanding Autoclave Calibration and Validation: An Overview

What is Autoclave Calibration?

Calibration is about making sure the temperature sensor in your autoclave is accurate. This is done by comparing it to a device that's already been calibrated, known as the "standard." Your autoclave technician should follow the national reference standards for this process, and by doing so will ensure that your autoclave is completing the sterilisation process as intended.

What is Autoclave Validation?

Validation ensures your autoclave reaches the right temperature for the right amount of time to effectively sterilise tools and biological agents. This is a quality assurance step to assess the autoclave's performance and ensure sterilisation is achieved. Biological indicators are also used to confirm the sterilization process is efficient and effective.

Why Calibrate and Validate Your Autoclave?

Regular calibration and validation are crucial for consistent sterilisation results. Autoclaves rely on precise temperature and pressure, so these processes ensure optimal conditions for proper sterilisation, keeping your instruments safe to use.

How are Autoclaves Calibrated?

Calibration involves comparing your autoclave’s readings with those of a device known to be accurate according to appropriate standards.

How Often Should Autoclaves Be Calibrated?

In Australia, autoclaves should be calibrated at least once a year. Heavily used autoclaves might need this service more often, however annually is the minimum requirement.

Do I Need Documentation After Calibration and Validation?

Yes, after each process, your autoclave technician should document the date, results, and other relevant information in an autoclave validation log. You’ll be notified of the outcomes, and provided with a cirtificate indicating that your unit has been calibrated and validated. 

Do Repaired Autoclaves Need Calibration and Validation?

Absolutely. Calibration and validation are different from regular repairs. During the calibration and validation process, your technician will thoroughly check the heating cycle, temperature, duration, pressure, and steam penetration to ensure the autoclave functions correctly. Regular servicing also includes inspecting parts like filters, seals, sensors, pumps, and chambers to prevent unexpected breakdowns and downtime.

By following these steps, we help ensure your autoclave is reliable and effective, maintaining the highest standards of sterilisation for your practice.

ProMedCo B Class Range:


ProMedCo Autoclaves: Precision Sterilisation for Dentists, Ophthalmologists, Surgeons & Hospitals


For professionals, reliable sterilisation equipment is essential to keep operations running smoothly and efficiently. That’s where our ProMedCo Autoclaves come in. Built for performance and durability, these autoclaves are designed to deliver seamless, long-lasting sterilisation you can trust. With the ProMedCo B Class Autoclaves, you can count on years of trouble-free operation, making them the go-to choice for busy practices that require equipment they can rely on every day.
Designed to meet the stringent demands of medical professionals, the ProMedCo B&S Class Autoclaves deliver superior performance, reliability, and ease of use ensuring years of trouble-free operation.

Features:

  • Compliant with Australian Standards and entered in the ARTG, 314341. Our autoclaves meet the highest regulatory standards, ensuring optimal sterilisation for medical-grade instruments and providing peace of mind for professionals in critical fields.
  • Thomas Pump for Superior Performance: The inclusion of the trusted Thomas Pump ensures that our autoclaves deliver the highest levels of reliability, even in high-demand environments like surgical and hospital settings.
  • Flexibility & Capacity: The ProMedCo B&S Class Autoclave includes three trays, with the option to hold up to five for our larger models, offering ample capacity for sterilising a wide range of instruments. The large, easily accessible tank simplifies filling and cleaning, ensuring your equipment is always ready for use.
  • User-Friendly Operation: With an intuitive interface, operators can choose from quick-start pre-set cycles or custom-defined settings, ensuring ease of use even in busy environments.
  • Comprehensive Data Management: Featuring an inbuilt thermal printer and optional  USB storage, our autoclaves provide convenient access to both printed and electronic cycle records, making it easy to maintain compliance with regulatory requirements.
  • One of the Longest Warranties in Australia: With a standard two-year coverage* and options to extend for additional peace of mind, trust in ProMedCo’s quality and reliability, knowing you have long-term protection that outlasts many competitors.
  • Competitive Pricing & Guaranteed Reliability: With over 500 autoclaves sold across Australia, our track record speaks for itself. ProMedCo is the trusted name in sterilisation.


The Complete Package
When you purchase a ProMedCo Autoclave, you’re investing in more than just equipment:

  • Hands-On Expertise: Our team brings hands-on experience in infection control and sterilisation, offering expert guidance and ongoing support. We don’t just sell equipment, we ensure you’re fully equipped to meet regulatory standards.
  • Infection Control Training: We offer training designed to keep your business compliant with the latest infection control guidelines. Our experts will guide your team through best practices to help ensure safety, efficiency, and regulatory compliance.

Free Starter Pack with Every Purchase

Register for your free starter pack with your purchase to receive:

  • Helix Test Kit
  • Pouches & Indicators
  • Microfibre Cloth
  • Sterilisation Logbook
  • Thermal rolls

*Denotes 2 year or 2000 cycle warranty - whichever occurs first. (24 months on parts, 12 months on labour.)

You may also like


Recently viewed